1. First determine the position of the induction label on the product. If it is a label placed concealedly, the reference mark shall be determined. Then pass the side of the product with the label or reference mark as close to the surface of the decoding board as possible to ensure that the label can pass through the effective decoding area. (Generally, the decoding area of the non-contact decoder is within 10cm from the surface of the decoder)
2. The decoding of soft labels must pass through the decoding board horizontally, and all six sides (for large hexahedral products) must pass through the decoding board horizontally. The purpose is to avoid a dead angle between the decoding board and the soft label. The number of passes can only be reduced once you have mastered decoding angles.
3. The decoding speed is controlled at one item per second, and it cannot be too fast, otherwise there may be incomplete label decoding.
4. After the soft label is decoded by the decoding board, the customer will cause the system to alarm through the detection antenna when leaving, which means that the decoding is not successful. This may be due to the cashier's mistake in decoding; but if this situation occurs continuously, then The supervisor should be notified in time, indicating that the decoding equipment is faulty.